상세 보기
Feasibility and accuracy of continuous glucose monitoring in surgical intensive care unit patients: a single-center pilot study in South Korea
- Park, Hyojun;
- Gil, Eunmi;
- Lee, Joon Ho;
- Park, Chi-Min
WEB OF SCIENCE
1SCOPUS
1초록
Background: Continuous glucose monitoring (CGM) technology offers potential advantages over intermittent point-of-care testing in critically ill patients by providing real-time glucose trends and automated alerts. However, its accuracy and feasibility in intensive care settings require validation before widespread implementation. Methods: We conducted a single-center observational pilot study, evaluating CGM feasibility in 11 surgical intensive care unit (ICU) patients, including nine post-liver transplant recipients. The G6 CGM system was applied for continuous monitoring. CGM readings were paired with point-of-care glucose measurements for accuracy assessment. Performance metrics included the mean absolute relative difference (MARD), bias, standard deviation of relative differences (SDRD), Surveillance Error Grid (SEG) analysis, and International Organization for Standardization (ISO) 15197:2013 criteria compliance. Results: During a median monitoring period of 5 days (interquartile range [IQR], 3-9), we analyzed 326 paired glucose measurements. CGM demonstrated acceptable accuracy, with a MARD of 13.5% (95% CI, 11.43%-15.76%), bias of 2.79% (95% CI, -2.48 to 7.27%), and SDRD of 18.69% (95% CI, 13.75%-23.65%). SEG analysis confirmed 99.1% of readings were in clinically acceptable zones A and B. ISO 15197:2013 criteria showed 62.9% of measurements were within ±15 mg/dl or ±15%. The median patient-level mean glucose was 199.0 mg/dl (IQR, 162.0-248.0), reflecting substantial hyperglycemic exposure in patients receiving high-dose methylprednisolone despite protocolized insulin therapy targeting a range of 140-180 mg/dl. Conclusions: CGM was feasible and acceptably accurate in ICU patients. Persistent hyperglycemia despite protocolized care indicates that CGM-derived data may help to identify opportunities for future protocol improvement. Its potential impact on the time-in-target range, hypoglycemia, and clinical outcomes should be evaluated in future multicenter studies.
키워드
- 제목
- Feasibility and accuracy of continuous glucose monitoring in surgical intensive care unit patients: a single-center pilot study in South Korea
- 저자
- Park, Hyojun; Gil, Eunmi; Lee, Joon Ho; Park, Chi-Min
- 발행일
- 2026-05
- 유형
- Article
- 권
- 41
- 호
- 2
- 페이지
- 378 ~ 386
- 언어
- ENG
- 출판사
- Korean Society of Critical Care Medicine
- 발행국가
- 대한민국
- 분량
- 9 페이지
- ISSN
- E 2586-6060
P 2586-6052