Hydrogen blending into natural-gas pipelines is a practical transitional approach for large-scale hydrogen deployment. This study investigates how hydrogen blending ratio affects flow characteristics in an L-shaped pipe elbow with a Coanda-based mass flow amplifier. Using k-ω SST turbulence simulations and the Peng–Robinson equation of state, hydrogen blending ratio (ζ, mole fraction) was varied from 0 to 0.5 in increments of 0.1, together with a supplementary pure-hydrogen case (ζ = 1). Results showed that increased hydrogen blending decreased velocity magnitude and weakened the wall-attached jet, reducing entrainment. A momentum-flux analysis attributes this entrainment weakening to the fixed secondary-inlet velocity condition, a mechanism consistent with recent hydrogen-blending pipeline studies. Erosion rates decreased due to lower mixture density. At 50% hydrogen blending, the amplification ratio decreased by 25.98%, outlet mass flow rate by 55.19%, and pressure drop coefficient increased by 55.53%. These findings provide reference data for evaluating feasible hydrogen blending ranges in pipeline design and operation. © 2026 Authors.