상세 보기
Amyloid PET Quantitation and Centiloid Thresholds in the Diagnosis of Alzheimer Disease: An Individual Participant Data Meta-Analysis
- Blazhenets, Ganna;
- Soleimani-Meigooni, David N.;
- Chiotis, Konstantinos;
- Allen, Isabel E.;
- Rabinovici, Gil D.;
- ... Seo, Sang Won;
- 외 114명
WEB OF SCIENCE
4SCOPUS
4초록
Importance: Amyloid positron emission tomography (PET) is increasingly used in research and clinical settings to determine the etiology of cognitive decline and eligibility for amyloid-targeting therapies. To assist with amyloid PET evaluation and to guide clinical decision-making, images can be quantified in a standardized unit called Centiloid, the interpretation of which can vary according to the method and threshold used. Objective: To collect Centiloid values from available studies and determine robust positivity cutoffs using data-driven methods and correspondence with visual reads. Data Sources: PubMed search (October 2024) identified studies with Centiloid values. Corresponding authors were invited to share individual participant data. Additional data were obtained through access-controlled repositories and conference outreach (July 2024-July 2025). Study Selection: Studies were included if they provided Centiloids, radiotracer, age, and sex. Data Extraction and Synthesis: Each study was analyzed using a unified statistical pipeline; study estimates were pooled using random-effects meta-analysis. Main Outcomes and Measures: Gaussian mixture models (GMMs) were fitted to Centiloid values for each study. In studies with a bimodal distribution (per integrated completed likelihood), single cutoffs for positivity were set as mean plus 2 SDs of the lower gaussian component. Using GMMs, a double-cutoff approach defined a lower certainty range using a 90% posterior probability cutoff for assignment to the low (amyloid-negative) vs high (amyloid-positive) component. An alternative Centiloid cutoff was derived from maximizing the correspondence (Cohen κ) with the binary visual reads when available. Results: This meta-analysis included cross-sectional amyloid PET scans acquired with 5 radiotracers from 49227 participants across 53 studies from 15 countries (mean age, 71 years; 54% female, 62% cognitively impaired). The data-driven GMM approach identified a bimodal distribution in 51 studies (n = 48786), resulting in a single cutoff for positivity of 18 Centiloids (95% CI,16-19; I2 = 97%). The double-cutoff approach revealed high confidence for interpreting scans as negative when Centiloid values were lower than 11 (95% CI, 9-13; I2 = 95%) and interpreting scans as positive if Centiloid values were higher than 26 (95% CI, 24-28; I2 = 95%). In analyses of correspondence with binary (positive or negative) visual reads of amyloid PET scans (n = 35045; 36 studies), Centiloids were highly predictive of visual positivity (Cohen κ, 0.86; 95% CI, 0.83-0.89; I2 = 96%) with a cutoff of 27 Centiloids (95% CI, 24-30; I2 = 80%). Conclusions and Relevance: In this individual participant data meta-analysis, positivity cutoffs converged around 18 Centiloids (data-driven) and 27 Centiloids (visual reads). Findings from a double-cutoff analysis suggest that scans in the 11 to 26 Centiloid range should be interpreted with caution depending on the context of use.
- 제목
- Amyloid PET Quantitation and Centiloid Thresholds in the Diagnosis of Alzheimer Disease: An Individual Participant Data Meta-Analysis
- 저자
- Blazhenets, Ganna; Soleimani-Meigooni, David N.; Chiotis, Konstantinos; Allen, Isabel E.; Rabinovici, Gil D.; La Joie, Renaud; Apostolova, Liana G.; Asken, Breton M.; Bejanin, Alexandre; Benzinger, Tammie L. S.; Betthauser, Tobey J.; Bluma, Marina; Bombois, Stephanie; Bourgeat, Pierrick; Bouteloup, Vincent; Braskie, Meredith N.; Brendel, Matthias; Brickman, Adam M.; Bryant, Natalie; Bullich, Santiago; Carrillo, Maria C.; Casaletto, Kaitlin; Cash, David M.; Chang, Chiung-Chih; Chang, Hsin-I; Chao, Yishu; Chêne, Genevieve; Chételat, Gaël; Coath, William; Collij, Lyduine E.; Colmant, Lise; Corrada, Maria M.; Craft, Suzanne; Dickerson, Bradford C.; Dubois, Bruno; Dufouil, Carole; Fajardo, Alfonso; Farrar, Gill; Fortea, Juan; Frings, Lars; Frisoni, Giovanni B.; Gardner, Raquel C.; Garibotto, Valentina; Gnörich, Johannes S.; Gordon, Brian A.; Gu, Yuna; Guan, Yihui; Guo, Tengfei; Hanseeuw, Bernard J.; Hansson, Oskar; Harrison, Theresa M.; Huang, Qi; Huang, Shu-Hua; Iaccarino, Leonardo; Ishii, Kazunari; Ishi, Kenji; Jagust, William J.; Johnson, Sterling C.; Kato, Takashi; Katsumi, Yuta; Kaye, Jeffrey; Koeppe, Robert A.; Kolinger, Guilherme D.; Kramer, Joel H.; Landau, Susan M.; Landeau, Brigitte; Lao, Patrick J.; Lee, Sangwon; Lleó, Alberto; Lopresti, Brian J.; Lowe, Val J.; Luchsinger, Jose A.; Malpetti, Maura; Mao, Xiaoxie; March, Andrew; Masters, Colin L.; Meyer, Philipp T.; Mezenge, Florence; Mormino, Elizabeth C.; Franquesa-Mullerat, Maria; Nakamura, Akinori; Nordberg, Agneta; O'brien, John T.; O'bryant, Sid E.; Pappas, Ioannis; Peretti, Debora E.; Quenon, Lisa; Rowe, Christopher C.; Rowe, James B.; Rudolph, Marc D.; Salvadó, Gemma; Schott, Jonathan M.; Schwartz, Daniel L.; Schwarz, Christopher G.; Seo, Sang Won; Shekari, Mahnaz; Silbert, Lisa C.; Smith, Ruben; Snyder, Heather M.; Sokolowski, Andrzej; Sperling, Reisa A.; Sun, Pan; Taggett, Jacinda Z.; Toga, Arthur W.; Touroutoglou, Alexandra; Vaillancourt, David E.; Van De Giessen, Elsmarieke; Vijverberg, Jort; Vemuri, Prashanthi; Villain, Nicolas; Villemagne, Victor L.; Villeneuve, Sylvia; Wang, Wei-En; Weiner, Michael; Woodworth, Davis; Xiao, Cally; Xie, Fang; Yoon, Yeojun; Young, Christina B.; Yun, Mijin
- 발행일
- 2026-07
- 유형
- Article
- 언어
- ENG
- 출판사
- American Medical Association
- 발행국가
- 미국
- ISSN
- E 1538-3598
P 0098-7484