Comparison of Bruker Biotyper Sirius, VITEK MS PRIME, and ASTA MicroIDSys MALDI-TOF MS Systems for Cryptococcus Species Identification Across Protein Extraction Protocols

Citations

SCOPUS

0

초록

Background: Accurate and rapid identification of Cryptococcus spp. is critical for patient care. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is increasingly used for yeast identification; however, its performance varies with instrument and database coverage. We compared the performance of three MALDI-TOF MS systems-Bruker Biotyper Sirius (Sirius; Bruker Daltonics), bioMérieux VITEK MS PRIME (PRIME; bioMérieux), and ASTA MicroIDSys (ASTA; ASTA Inc.)-for detecting Cryptococcus spp. across protein-extraction protocols. Methods: We analyzed 51 C. neoformans, two C. deuterogattii, five Vanrija humicola, and one Naganishia liquefaciens clinical isolates. Each isolate was tested after on-plate formic acid extraction; isolates failing identification were retested after repeat on-plate and intube extractions. The results were categorized as correct, incomplete, incorrect, or no identification against ribosomal DNA sequencing results. Results: After initial on-plate extraction, correct identification rates were 86.4%, 88.1%, and 69.5% for Sirius, PRIME, and ASTA, respectively. After repeat on-plate extraction, ASTA accuracy increased to 81.4% (P =0.016). Additional in-tube extraction did not significantly improve identification across platforms, although PRIME outperformed ASTA (P =0.012). All platforms reliably classified C. neoformans (correct identification rates: 94%-96%) after additional on-plate extraction; discrepancies occurred mainly in uncommon species, possibly owing to gaps in database coverage. Conclusions: Sirius and PRIME demonstrated robust performance for C. neoformans identification and C. gattii complex differentiation, outperforming ASTA for relatively rare species. Single on-plate extraction is sufficient in clinical practice. However, continued database expansion is essential for maximizing MALDI-TOF MS performance and accurately identifying Cryptococcus spp., thereby informing antifungal therapy and improving patient outcomes.

키워드

ASTA MicroIDSys; Cryptococcus; MALDI-TOF MS; On-plate extraction; Sirius; VITEK MS
제목
Comparison of Bruker Biotyper Sirius, VITEK MS PRIME, and ASTA MicroIDSys MALDI-TOF MS Systems for Cryptococcus Species Identification Across Protein Extraction Protocols
저자
Park, Bosung; Suh, Eunsang; Won, Eun Jeong; Kim, Tae Yeul; Huh, Hee Jae; Sung, Heungsup; Kim, Mi-Na
DOI
10.3343/alm.2025.0497
발행일
2026-11-01
유형
Article
저널명
Annals of Laboratory Medicine
권
46
호
6
페이지
711 ~ 720