Comparative analysis of 6-lead and single-lead consumer-grade electrocardiograms: diagnostic accuracy, numerical agreement, and inter-rater reliability

Citations

WEB OF SCIENCE

0
Citations

SCOPUS

0

초록

Aims Consumer-grade electrocardiogram (ECG) devices enable accessible rhythm monitoring. Recently developed six-lead handheld ECGs promise improved signal quality and diagnostic performance; however, comparative validation remains limited. Using 12-lead ECGs as reference, we compared diagnostic performance and quantitative agreement of a 6-lead and single-lead consumer ECGs.Methods and results In this prospective single-centre study, 194 arrhythmia-clinic patients (498 paired recordings) underwent simultaneous 10-s 12-lead and 30-s 6-lead ECG acquisition, followed by sequential 30-s single-lead recording. Two blinded electrophysiologists interpreted ECGs. Diagnostic performance for predefined rhythm categories (sinus rhythm, atrial/ventricular premature complex, atrial fibrillation/flutter/tachycardia, atrioventricular block, others) was assessed by sensitivity, specificity, and accuracy. Waveform agreement was evaluated using Bland-Altman analysis and intraclass correlation coefficients (ICC) accounting for repeated measures. Sensitivity was higher for the 6-lead ECG for ectopic beats, atrial flutter, and first-degree atrioventricular block, with comparable specificity across categories. Overall diagnostic accuracy was 98.6% (95% confidence interval, 97.4-99.6) for the 6-lead and 96.9% (94.7-98.7) for the single-lead ECG. Agreement with the 12-lead ECG was higher for the 6-lead device for PR interval (ICC 0.89; 0.85-0.92) and QRS amplitude (0.96; 0.94-0.97) than for the single-lead device (0.57; 0.48-0.63 and 0.04; -0.13-0.21, respectively). Bland-Altman analysis demonstrated generally narrower limits of agreement for the 6-lead ECG. Findings were consistent in patient-level sensitivity analyses.Conclusion The 6-lead handheld ECG demonstrated a higher point estimate for diagnostic accuracy and closer agreement with the 12-lead ECG than the single-lead smartwatch ECG, supporting its use for arrhythmia assessment and interval measurement.

키워드

Wearable ECG devices; 6-lead electrocardiogram; Single-lead electrocardiogram; Diagnostic accuracy; DETECT ATRIAL-FIBRILLATION; HAND-HELD; CLINICAL VALIDATION; CARDIOLOGY; DEVICES; ECG
제목
Comparative analysis of 6-lead and single-lead consumer-grade electrocardiograms: diagnostic accuracy, numerical agreement, and inter-rater reliability
저자
Kim, Myoung Jung; Eom, Sujeong; Kim, Juwon; Park, Seung-Jung; Park, Kyoung-Min; On, Young Keun; Joo, Sunghoon; Chang, Mineok; Na, Yeongyeon; Park, Minje; Lim, Jeonghwa; Yu, Taehyung; Ahn, Hyun Jin; Kim, Ju Youn
DOI
10.1093/ehjdh/ztag086
발행일
2026-07
유형
Article
저널명
EUROPEAN HEART JOURNAL - DIGITAL HEALTH
권
7
호
6