Optimization, validation, and measurement uncertainty of HPLC-UVD method for quantification of thaumatin in food
  • Park, Hyeon-Ju
  • Yun, Choong-In
  • Kim, Do-Yeon
  • Kim, Young-Jun
Citations

WEB OF SCIENCE

1
Citations

SCOPUS

1

초록

Thaumatin is a low-calorie protein sweetener extracted from Thaumatococcus daniellii Benth. Its ADI (Acceptable Daily Intake) was concluded as "not specified" by the EFSA (European Food Safety Authority). This study was conducted to select a sample preparation method and validate the proposed method by applying a matrix-matched calibration curve using HPLC-UVD. In the results, the calibration curve (5-200 mg/L) represented good linearity (r2 >= 0.9995). LOD and LOQ ranged from 1.28 to 2.00 mg/L and from 3.89 to 6.07 mg/L, respectively. The intra- and inter-day accuracies and precisions ranged from 91.5 to 103.0%RSD and from 0.50 to 3.42%RSD, respectively. Furthermore, the relative expanded uncertainty was evaluated and the result satisfied the CODEX guideline (<= 16%). Additionally, the application of the validated method was confirmed by using thaumatin-containing foods distributed in Korea. Thaumatin intake and exposure assessments for consumers can be conducted based on this study.

키워드

Food additiveMethod validationMeasurement uncertaintySweetenerThaumatinPROTEINS
제목
Optimization, validation, and measurement uncertainty of HPLC-UVD method for quantification of thaumatin in food
저자
Park, Hyeon-JuYun, Choong-InKim, Do-YeonKim, Young-Jun
DOI
10.1007/s10068-025-01823-0
발행일
2025-02
유형
Article; Early Access
저널명
Food Science and Biotechnology
34
9
페이지
1849 ~ 1856