상세 보기
Impact of Mutual Inductance Variation on Fault-Tolerant Operation of Dual Three-Phase PMSMs
- Yang, Hye-Won;
- Park, Seah;
- Park, Dong-Hyeon;
- Jung, Sang-Yong
SCOPUS
0초록
Dual three-phase permanent magnet synchronous machines (DTP-PMSMs) are widely used in high-reliability applications, but the inter-set electromagnetic coupling can amplify transient disturbances under fault conditions. This paper investigates the influence of inter-set mutual inductance M on the three-phase short-circuit fault transient of DTP-PMSMs. Using a winding-function-based formulation, four configurations are constructed as a 2×2 matrix of phase displacements (0°, 30°) and coil pitches (6-slot, 7-slot). Time-domain FEM simulations reveal a monotonic correlation between M and fault severity. Varying M by a factor of two (0.114–0.225 mH) reduces the short-circuit current overshoot by 12% and the torque dip by 18%, and prototype measurements validate the FEM model used to derive these design guidelines.
키워드
- 제목
- Impact of Mutual Inductance Variation on Fault-Tolerant Operation of Dual Three-Phase PMSMs
- 저자
- Yang, Hye-Won; Park, Seah; Park, Dong-Hyeon; Jung, Sang-Yong
- 발행일
- 2026
- 유형
- Article
- 언어
- ENG
- 출판사
- Institute of Electrical and Electronics Engineers Inc.
- 발행국가
- 미국
- ISSN
- E 1941-0069
P 0018-9464